High Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery

Type: Skin Graft Mesher
Application: Burns Surgical
Material: Steel
Certification: CE, ISO13485
Group: Burn Patients
Product Name: Skin Graft Mesher
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (14)

Basic Info.

Model NO.
CHW-MT5
N.W
11.5kg
G.W
12.5kg
Package Dimensions
59*40*31cm
Transport Package
Carton
Trademark
ICLEAR
Origin
China
Production Capacity
50pieces/Day

Product Description

High Quality Multi-use Skin Graft Mesher for Burns Surgery 
CHW-MT5

High Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery
Features:
The design of this machine perfectly combines the technology of cutting small square skin grafts and expanding reticular skin grafts into the same machine. The width of skin grafts being treated can reach nearly twice of traditional machines. The length can actually be unlimited.
1. We suggest autoclave sterilization or low-temperature plasma sterilization.
2. The warranty period is one year. After a year, a certain amount of maintenance fees will be paid each year for a continuous warranty.


Components & Basic parameters:
1. Mainframe   
2. Continuous feed roller
3. Ratchet handle
4. Expansion/cutting rollers
4.1 Cutting roller for square skin graft 
Standard specification: 7x7mm
Optional specifications: 3x3mm;5x5mm;10x10mm;12x12mm;20x20mm
4.2 Expansion roller for reticular skin graft
Standard specification: 1:2
Optional specifications: 1:1;1:1.5;1:3;1:4;1:5;1:6 


Technical Parameters
1. Product Name: Skin Grafting Multi-use Machine
2. Machine Model: CHW-ET5
3. Standard Expansion/Cutting Rollers: 2 Pcs

4. Two Functions:  
4.1 Specifications of Cutting Rollers for Square Skin Graft:  
7*7mm    (Standard 1 Pc)
3*3mm, 5*5mm, 10*10mm, 12*12mm,20*20mm    (Optional 5 Pcs)
4.2 Specifications of Expansion Rollers for Reticular Skin Graft:  
1:2       (Standard 1 Pc)
1:1,1:1.5,1:3,1:4,1:5,1:6                         (Optional 6 Pcs)
5. Specification of Skin Graft can be processed:
5.1 Max Width≥110mm
5.2 Max Length: Unlimited
5.3 Max Thickness: Unlimited
6. Function Realization Method: Changing expansion/cutting rollers
7. Operation Method of Machine: Manual
8. Sterilization Method: pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, etc.

9. The whole device and rollers are anti-corrosive, the rollers are sharp and will not be rusty.
10. Non-die roller design, longer lifetime, a single blade can be replaced, lower maintenance cost.

Cleaning and Maintenance Guidance
1. Preparation before use:
Before clinical use of skin graft mesher, the whole machine and skin graft carriers should be wrapped with gauze, then put into an autoclave case, tighten the cover completely. Send them together to the sterilization room for sterilization. Please choose pre-vacuum and gravity displacement steam sterilization or low-temperature plasma sterilization, after autoclave sterilization, the set dry cooling time is at least 8 minutes.
2. Cleaning after use:
After the machine is used, wash away the scraps on the roller with a soft brush or gauze; Finally, the roller should be wiped clean with oil gauze or blown to dry with an air gun, water stains can not be retained on the roller.
Depending on the detailed situation, the whole machine need not be scoured, it just needs to be wiped with oil gauze.
The whole machine should be stored in a dry environment.
( Note: the whole machine should be cleaned and wiped with distilled water(pure water)or alcohol, oil gauze, do not allow the operator to use normal saline or iron brush to wash it!)
3. Storage:
The cleaned whole machine should be stored in a dry and ventilated place at room temperature, and it should be placed in an autoclave case or machine box.

Precautions and safety warnings:
Precautions:
1.This device can only be used by a trained or professional surgeon.
2.In order to ensure the accuracy of the expansion/cutting roller, please replace it every 1000 times.
3.The blades are very sharp, avoid contact with hands directly.
4. Please just use our company's carriers, otherwise, it will damage the expansion/cutting rollers.
Safety precautions:
1.Select proper expansion/cutting roller according to specifications.
2.After using the machine, the expansion/cutting roller should be removed incorrect way.
3.Dispose the carrier according to disposable medical product regulations.  
4.The machine must not be soaked in saline solution.

High Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery
High Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery
High Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns SurgeryHigh Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery
Related Recommends
High Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery

Company Information
High Quality Medical Multi-Use Skin Graft Mesher for Burns Surgery
FAQ
> if the machine broke after a period of use, can I return it back and get a refund?
iClear HealthCare has a secure procedure to do the product return and repair, please check our service
policy for more information.

 

> I have NO experience buying medical stuff in China. Is the quality good?
There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price.

 

> How long will it take to reach me after the payment?
By Express, it takes 5-7 working days to arrive;
By Air, 3-4 days to the international airport;
By Sea, around 25-55 days to the seaport.

 

>> Can you help set up a clinic or provide complete equipment for hospital projects?
We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now