5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter

Product Details
Customization: Available
Certification: CE, ISO
Measuring Range: up to 50000j
Manufacturer/Factory, Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (15)
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
  • 5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
Find Similar Products

Basic Info.

Model NO.
CHL-5E-C5500
Temp.Resolution
0.0001degree
Control Ability
2 Units/ 1 PC Available
Analysis Time Per Sampletdynamic Method
10mins, Classical Method:15mins
Test Per Hour: Single Control
up to 6 Double Control: up to 12
Bucket Filling
Automatic
Oxygen Filling
Semi-Automatic
Structure
Benchtop or Vertical
Net Weight
Bench Top: 75kg Vertical Type: 103kg
Dimensions (L*W*H)
Bench Top: 480mm*500mm*420mm (Analysis Unit) 370mm
Transport Package
Wooden Packing
Trademark
ICLEAR
Origin
China
Production Capacity
300pieces/Year

Product Description

5E-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
CHL-5E-C5500


Automatic Calorimeter is used to determine the calorific value of solid and liquid combustibles including oil, coal, coke, foodstuffs and biomass products. The calorific value is a crucial characteristic for each substance, also the key point to calculate the price of coal, so it will directly affect the economic benefits of the customers. This technique is widely applied in power plants, coal mines, metallurgy, chemical industry, commercial inspection, scientific research, etc.

Standard Configuration:
Main analyzer: Controlling Unit and Chiller
Standard CV bomb
Data System (PC & Printer)
Handle Oxygen Charger
Crucibles
Ignition Wire
Benzoic Acid
O-ring kit
Tool kit


Optional Configuration:
Lens paper
Pellet press
Bench-top oxygen charger
Halogen Resistant Oxygen Vessel


Features:
True Isoperibol Calorimeter
The jacket surrounding the vessel is kept at constant temperature with an accuracy to 0.1ºC during analysis.Mechanical supports for the vessel are made of a very lowthermal conductivity plastic. To minimize convention,water is added on the sides,top and bottom of the bucket.


High Automation and Efficiency
1. Dynamic method available, without compromising accuracy or precision.
2. Second oxygen vessel and sample can be prepared while the current sample is being analyzed.
3. Two calorimeters can be controlled by one computer.Sample mass can be transferred to PC directly. 


Optimized Design for Reliable Test Result
1. A reliable quantitative measuring cup ensures stable water volume of the bucket.
2. Closed-loop water circulation assures the purity of water system without any additional solution.
3. Filter in the bucket purify the water in circulation system.
4. Visible water level indicates the water volume, making it easy to feed sufficient water anytime to minimize the influence of water loss.
Model  Automatic Calorimeter
Conforms to Method AS 1038.5, ASTM D5865, ASTM D4809, ASTM E711, BIS 1350, BS EN 15400, GB/T 213,GB/T 30727, ISO 1928, ISO 9831,ISO 18125
Precision (1g Benzoic Acid) 0.05% RSD *
Measuring range Up to 50000J
Temp.Resolution 0.0001ºC
Control Ability 2 Units/ 1 PC available
Analysis Time per Sample Dynamic method:10mins, Classical method:15mins
Test Per Hour Single control Double control
Up to 6 Up to 12
Jacket Type Isoperibol
Bomb Identification Up to 2 for automatic, several for manual
Balance Connection Available
Network Connection Available
Bucket Filling Automatic
Oxygen Filling Semi-Automatic
Structure Benchtop or Vertical
Bomb Vessel Lifting Manual
Power Supply Single-phase, AC220V±10%, 50/60Hz, ≤500w
Net Weight Benchtop: 75kg
Vertical type: 103kg
Dimensions(L×W×H) Benchtop:
480mm×500mm×420mm (Analysis unit)
370mm×500mm×420mm (Temp. control unit)
Vertical: 480mm×500mm×940mm
*Test Condition: 1. Ambient temp.20ºC±1ºC,humidity75%±5%  2.No strong interference source nearby  3.Clean water circuit with distilled water

5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
Spare parts
1. Oxygen vessel holder
2. Exhaust valve
3. Bench-top oxygen charger
4. Handle oxygen charger
5. Wipe cloth
6. Ignition wire
7. Crucible
8. Bomb lift
9. Mainboard
10. Ignition board
11. Temperature measuring board
12.  Solid-state relay
13. Relay
14. Transformer
15. Switching power supply
16. Control panel
17. Serial wire with magnetic ring
18. Measuring vessel
19. Pressure reducing valve
20. Magnetic pump
21. Crucible holder
22. Three-core power wire
23. O-ring-12×3
24. O-ring-18×2.4
25. O-ring-12×2
26. O-ring-16×2.65
27. O-ring-60×5.7
28. O-ring-6×1.9
29. O-ring (Bucket)
30. Guide pipe components
31. Pressing machine
32. Benzoic acid
33. standard coal
34. Probe (Bucket)
35. Suspender II
36. Suspender I
37. Crucible
38. Lens paper
39. Oxygen vessel
Related Recommends
5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter

Company Information
5e-C5500 Laboratory Automatic Oxygen Bomb Calorimeter
FAQ
> if the machine broke after a period of use, can I return it back and get a refund?
iClear HealthCare has a secure procedure to do the product return and repair, please check our service
policy for more information.

 

> I have NO experience buying medical stuff in China. Is the quality good?
There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price.

 

> How long will it take to reach me after the payment?
By Express, it takes 5-7 working days to arrive;
By Air, 3-4 days to the international airport;
By Sea, around 25-55 days to the seaport.

 

>> Can you help set up a clinic or provide complete equipment for hospital projects?
We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More