• Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
  • Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
  • Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
  • Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
  • Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
  • Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices

Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices

Type: Patient Monitoring Devices
Certification: CE
Weight: 2.0 Kg
Adapter: 9 (V) DC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºC
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2019

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (14)

Basic Info.

Model NO.
CHO-PM1
Maximum Input Power
150va
Transport Package
Carton
Specification
192 mm(L) × 162 mm(W) × 243 mm(H)
Trademark
ICLEAR
Origin
China
Production Capacity
500 Sets/Month

Product Description

Touch Screen Portable Ambulance Multi Parameter Vital Sign  Patient Monitoring Devices
CHO-PM1
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Introduction
This device can monitoring such parameters as ECG, RESP, SpO2, PR, NIBP and TEMP, etc. It integrates parameter measurement module,display and recorder in one device to form a compact and portable equipment.
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, single-channel TEMP
1)ECG Heart rate(HR)
ECG waveform
Arrhythmia and ST-segment analysis
2)RESP Respiration rate(RR)
Respiration waveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP Temperature
It has abundant functions, such as touch-screen operation, audible and visual alarm, trend data storage and output, NIBP
measurement, alarm event marking and drug concentration calculation, etc.
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Performance
ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR
Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2 mV ~ +2 mV
Accuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
RESP
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150 rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 12.5 mm/s, 25 mm/s
NIBP
Method: Oscillometry
Mode: Manual/AUTO/Continuous
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 minutes
Measurement period in Continuous mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximum mean deviation: ±5 mmHg
Maximum standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHg
SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
TEMP
Channel: single-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºC
Power supply
Adapter: 9 (V) DC
AC: 100 ~ 240 (V), 50/60 (Hz)
Safety classification: Class I, type CF defibrillation-proof applied part
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Accessories
Adult fingertip SpO2 probe
SpO2 probe extension cable
Adult NIBP cuff
NIBP extension tube
ECG lead cable
ECG electrode
Temperature probe
Power cord
Power adapter
User Manual

Physical characteristic
Dimension: 192 mm(L) × 162 mm(W) × 243 mm(H)
Weight: 2.0 Kg
 

Related Recommends

Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
Company Information
Touch Screen Portable Ambulance Multi Parameter Vital Sign Patient Monitoring Devices
FAQ
> if the machine broke after a period of use, can I return it back and get a refund?
iClear HealthCare has a secure procedure to do the product return and repair, please check our service
policy for more information.

 

> I have NO experience buying medical stuff in China. Is the quality good?
There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price.

 

> How long will it take to reach me after the payment?
By Express, it takes 5-7 working days to arrive;
By Air, 3-4 days to the international airport;
By Sea, around 25-55 days to the seaport.

 

>> Can you help set up a clinic or provide complete equipment for hospital projects?
We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now