Classification: | Biochemical Apparatus |
---|---|
Type: | Automated Microbial ID/Ast System |
Certification: | CE, ISO13485 |
60 IST Cards Fully Automated Microbial ID/AST System with Incubator and Dispenser
CHL-DL96A
Parameter
Capacity | 60 cards |
Report time | up to 8 hours |
Weight | 125kg |
Size | 945mm*700mm*1080mm |
Power | AC 110~ 240 VAC (50-60 Hz) |
Environmental Requirements | |
Operating Ambient Temp. | 15C to 30"C |
Operating Humidity Range | 20% to 80% relative humidity, non-condensing |
Feature & Principle
-Fully automatic operation.
-Detection and analysis of microbial infection.
-Capacity: 60 IST cards.
-Identify around 500 kinds of microorganisms, and cover 200 kinds of antibiotics with the latest CLSI regulation.
-Divide the antibiotics into 4 groups by expert analysis system, providing True MIC and SIR results.
Technical specifications
-Fully automated closed system (sample insertion, incubation, reading of results, interpretation of results);
-Simultaneous identification of a microorganism and determination of its sensitivity to antibiotics in one panel;
Advantages
-The identification of microorganisms is carried out by two methods: colorimetry and turbidity;
-Registration of the growth of microorganisms is carried out by the device according to two parameters: Cell replication score and assessment of the metabolic activity of the cell.
-The determination of sensitivity to antibiotics should be carried out by the degree of turbidity and by changing the redox potential.
-Determination of sensitivity to antibiotics by serial microdilution method to detect the minimum inhibitory concentration of antibiotic: Definition of "delayed resistance" with the prediction of the development of stability, and the results of the identification of microorganisms could be nearly 5 hours, antibiotic Sensitivity Results could be nearly 8 hours.
-Sound and visual notification of the presence of a positive sample with an indication on the display of the location of the positive sample.
-For the number of identified microorganisms, there are not less than 140 Gram-positive aerobic and facultative anaerobic bacteria and not less than 160 Gram-negative aerobic and facultative anaerobic bacteria;
-The sensitivity of microorganisms is determined by at least 25 antibacterial drugs;
-Special tests include Extended-Spectrum Beta-Lactamase (ESBL) and methicillin-resistant staphylococci (MRS).
-Saving the results of the analysis in the memory of the device for not less than 30 days.
-A nephelometer for measuring the turbidity of suspensions of microorganisms in the range of at least 0- 6.0 according to the McFarland standard with a calibration kit: at least 1 set.
> if the machine broke after a period of use, can I return it back and get a refund? iClear HealthCare has a secure procedure to do the product return and repair, please check our service policy for more information. |
> I have NO experience buying medical stuff in China. Is the quality good? There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price. |
> How long will it take to reach me after the payment? By Express, it takes 5-7 working days to arrive; By Air, 3-4 days to the international airport; By Sea, around 25-55 days to the seaport. |
>> Can you help set up a clinic or provide complete equipment for hospital projects? We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers. |